NeoScale

NeoScale high-speed optical dispensing metrology replaces traditional collection and gravimetric weighing with non-contact image analysis. It enables rapid evaluation of single-shot dispensing volume and jetting consistency, substantially reducing inspection time while delivering digitized data for advanced equipment and process analytics.

Optic

Measurement principle

Optical Measurement & Response Time

NeoScale converts optical information into quantitative dispensing data, revealing individual-shot and short-cycle variation that conventional averaged weighing can overlook.

Optical Data Capture

A camera, precision illumination, droplet edge detection, image processing, and calibration algorithms identify droplet contours, dimensions, and geometric features from optical images.

Quantitative Evaluation

A calibration model translates optical geometry into dispensing data, making it possible to evaluate consistency as valve condition, nozzle condition, and process parameters change.

Measurement workflow

From captured image to actionable evaluation.

A continuous four-stage workflow turns droplet imagery into process information.

  1. 01Imaging
  2. 02Detection
  3. 03Analysis
  4. 04Evaluation

Rapid

Response advantage

Rapid Dispensing Qualification

NeoScale shortens the path from parameter adjustment to validated dispensing conditions, particularly for automated qualification involving large nozzle arrays, multi-valve systems, or multiple process recipes.

Conventional method

Gravimetric Measurement

Typically requires accumulation of multiple droplets to produce a sufficient mass signal, making it better suited to offline or sampling-based inspection.

NeoScale method

Rapid Optical Measurement

Quickly compares dispense quantity changes caused by pressure, pulse duration, valve opening settings, temperature, or material conditions.

Process impact

Faster feedback accelerates automated qualification and process-window development while exposing variations between individual shots or short dispensing cycles.

Link

Equipment integration

NeoScale Automatic Dispensing Check Station

NeoScale is designed around measurement module integration and automated verification. Its non-contact architecture can be integrated into automated dispensing equipment without the weighing pan, liquid collection vessel, and stringent vibration isolation required by conventional precision balances.

Equipment can automatically move the jet valve to the measurement position before production, after material changeover, following a recipe change, during scheduled maintenance, or in response to an anomaly.

No Settling Time

No balance settling time is required.

Evaporation Resistance

Minimal influence from liquid evaporation.

Vibration Resistance

Minimal influence from environmental vibration.

Multiple Outputs

Weight, droplet behavior, and nozzle condition in one workflow.

Verification Triggers — Before production, after material changeover, following a recipe change, during scheduled maintenance, or in response to an anomaly.

Integration Benefits — Measurement does not rely on collecting liquid on a weighing pan. Liquid capture and waste handling must still be addressed in the equipment design.

View

Seven functions

Dual-View Droplet Observation & Analysis

Two optical perspectives connect nozzle condition with complete droplet geometry and flight behavior.

Dual-View Observation Configuration

NeoScale dual-view droplet observation

Dual-View Observation: 0° X/Z and 90° Y/Z

Nozzle Monitoring & Droplet Analysis

Nozzle Monitoring

  • Nozzle Residue Factor

Droplet Calculations

  • Droplet Volume
  • Satellite Droplets
  • Droplet Length
  • Droplet Diameter / Width
  • 3D Flight Angle
  • Droplet Velocity

Time

Cycle comparison

Measurement Workflow & Cycle Time Comparison

Conventional balance and NeoScale cycle time comparison

Conventional Precision Balance

Dispensing: 1 s + Settling: 2 s

Total Cycle Time: 3.0 s

NeoScale

Dispensing: 0.2 s + Analysis: 0.1 s

Total Cycle Time: 0.3 s

The workflow illustration specifies a balance settling time of 2 s, whereas the table below lists 5 s. Both values are retained from the source material. The manufacturer should confirm whether different test conditions apply.

Versus

Measurement comparison

Conventional Precision Balance vs. NeoScale

CharacteristicConventional Precision BalanceNeoScale
Precision1 µg0.001 µg
Required Shots> 100 shots> 5 shots
Effect of Liquid EvaporationSevereAlmost None
Effect of Environmental VibrationSensitiveAlmost None
Result OutputOverall Weight
  • Overall Weight
  • Single-Shot Weight
  • Satellite Droplet Weight
  • Flight Angle
  • Droplet Velocity
  • Droplet Dimensions
  • Nozzle Residue
Settling Time5 s0 s
Start-up Time60 min1 min

Comparison data are based on MOL internal testing and are provided for technical reference only. Actual performance depends on material, equipment configuration, and test conditions. “Precision” is retained from the source terminology and should not be interpreted as a guaranteed accuracy specification.

Control

PROCESS MANAGEMENT APPLICATIONS

Process Management & Data-Driven Control

Process Traceability & Preventive Maintenance

In process management, NeoScale does more than replace an electronic balance. More importantly, it digitizes dispensing measurement. Each measurement result can be associated with the Valve ID, Nozzle ID, recipe, material, time stamp, and equipment parameters, moving dispensing quality management from conventional manual sampling toward automated, traceable, data-driven control.

Build Complete Process Context from Every Measurement

  • Valve ID
  • Nozzle ID
  • Recipe
  • Material
  • Time Stamp
  • Equipment Parameters

Apply

KEY APPLICATIONS

Bring Measurement into Production-Line Management

NeoScale can use brief periods of process dead time to perform high-speed optical calibration. Its compact mechanical design supports next-to-line deployment, allowing measurement and verification without substantially disrupting production cadence.

High-Speed Optical Calibration

Rapidly inspect dispensing conditions with non-contact optical measurement while reducing the waiting and accumulation time required by conventional gravimetric measurement.

Use Brief Process Dead Time

Perform checks during material changeover, line change, recipe switching, maintenance, or anomaly response to make effective use of brief process dead time.

Next-to-Line Integration

The compact mechanical design supports next-to-line deployment and integration with automated handling, valve positioning, and equipment-control workflows.

DATA ASSOCIATION

Data Association

  • Valve ID
  • Nozzle ID
  • Recipe
  • Material
  • Time Stamp
  • Equipment Parameters

MANAGEMENT APPLICATIONS

Management Applications

  • SPC
  • Process Traceability
  • Nozzle-to-Nozzle Comparison
  • Valve Aging Monitoring
  • Preventive Maintenance

PROCESS IMPACT

Move from manual sampling to automated, data-driven control. NeoScale transforms every dispensing measurement into traceable process data to support statistical control, nozzle-to-nozzle comparison, valve-aging monitoring, and preventive maintenance.