UltiStrobe

Combining 3D optical observation, virtual image analysis, and a web-based interface, the UltiStrobe High-Precision Droplet Analysis System accurately measures droplet volume, morphology, flight velocity, trajectory, ligament length, and projected impact points, making it ideal for both laboratory R&D and automated equipment integration.

Ultra

Droplet intelligence

UltiStrobe High-Precision Droplet Analysis & Process Monitoring

UltiStrobe is a high-precision droplet observation platform for non-contact dispensing and inkjet systems. Optical imaging and analysis translate droplet formation, flight behavior, and nozzle condition into actionable process information. Engineers can evaluate droplet volume, flight direction, satellite droplets, and predicted landing position to support jetting parameter optimization and dispensing quality assessment.

Precision 3D Droplet Analysis

Precision Drop Analysis

3D droplet observation enables evaluation of volume and flight direction while identifying satellite droplets that may be obscured by the main droplet. Predicted landing position extends the analysis beyond droplet size to jetting direction and placement performance.

Analysis Focus | Volume, direction, satellites, and predicted landing position

Droplet Formation & Dynamics

Virtual Video Analysis

The virtual video function visualizes droplet formation, elongation, breakup, and splashing over a specified time range and temporal resolution, revealing dynamic behavior that cannot be captured in a single image.

Analysis Focus | Formation, tailing, breakup, and splashing

Nozzle Condition Monitoring

Nozzle Monitoring

Observe liquid residue at the nozzle and its influence on jetting behavior. This helps determine whether changes in droplet volume or flight direction are associated with nozzle condition and supports cleaning and maintenance decisions.

Analysis Focus | Nozzle residue and jetting anomalies

Browser-Based Operation & Analysis Setup

Web-Based User Interface

The AnalysisUnit incorporates a web server for configuring analysis functions, acceptance criteria, statistical analysis, GPIO, and database connections through a standard browser without dedicated software installation.

Operation Focus | Analysis setup, statistics, and data interfacing

Data

Measurement parameters

From Droplet Formation to Landing Position

Evaluate jetting quality using the parameters relevant to your process. Predicted landing position is calculated from droplet flight information; it is not a direct measurement of the actual landing position on the substrate.

Droplet volume analysis diagram

Droplet Volume

Evaluate liquid volume per droplet and changes caused by parameter adjustments.

Droplet flight velocity analysis diagram

Flight Velocity

Analyze flight velocity to support adjustment of jetting conditions.

Droplet flight direction diagram

Flight Direction & Angle

Observe jet deflection and directional consistency.

Droplet shape analysis diagram

Droplet Shape

Examine contours and deformation during formation.

Ligament analysis diagram

Ligament Length & Tailing

Observe ligament extension and breakup behavior.

Satellite droplet diagram

Satellite Droplets

Identify small droplets surrounding the main droplet.

Stability analysis diagram

Drop-to-Drop Stability

Compare successive droplets to evaluate repeatability.

Predicted landing diagram

Predicted Landing Position

Estimate placement deviation risk from flight information.

Link

System integration

Optical Configuration & Equipment Interfacing

UltiStrobe software and hardware integration diagram

UltiStrobe Software & Hardware Integration

Flexible Optical Configuration

Supports S-Mount and C-Mount lenses selected according to droplet size, field of view, resolution, working distance, and backlight requirements.

Laboratory & Equipment Integration

Use LabStand for benchtop testing or integrate the system into dispensing equipment with appropriate mounting accessories.

Droplet detection capability, measurement range, and analysis performance depend on optics, illumination, and system configuration. Refer to the manufacturer's specifications and application validation results.

3D Droplet Analysis · Droplet Formation Dynamics · Nozzle Condition Monitoring · Browser-Based Operation · Flexible Optics

Lens

Optical selection

UltiStrobe Lens Selection

Compare magnification, field of view, resolution, working distance, and lens mount to identify the optical configuration suited to your process.

LensMagnificationField of View [mm]Resolution [µm/px]Working Distance [mm]Lens Mount
S-1.01.03.9 × 4.452.7915S-Mount
S-2.02.01.95 × 2.21.3915S-Mount
C-0.50.57.8 × 8.95.5875C-Mount
C-1.01.03.9 × 4.452.7969C-Mount
C-2.02.01.95 × 2.21.3965C-Mount

Tools

Accessories

Integration & Calibration Accessories

Purpose-built accessories simplify benchtop setup, inline mounting, illumination, calibration, and trigger interfacing.

LabStand

UltiStrobe LabStand

Benchtop Mounting & Positioning Platform

Slotted aluminum baseplate with precision X/Y/Z positioning for laboratory or production testing.

Inline Mount

UltiStrobe Inline Mount

Dispensing Head Mounting Bracket

Attaches UltiStrobe directly to the dispensing head for inline droplet monitoring.

Backlight

UltiStrobe backlight

High-Power Stroboscopic Backlight

Multiple configurations match lens and application requirements for rapidly moving droplets.

GaugeAdapter

UltiStrobe GaugeAdapter

Camera Measurement Calibration Adapter

Plug-in design simplifies verification and adjustment of camera calibration values.

TriggerAdapter

UltiStrobe TriggerAdapter

Trigger Signal Interface Adapter

Provides the UltiStrobe trigger interface without modifying compatible existing wiring.

Accessory compatibility, installation requirements, and supplied configurations are subject to the selected lens, dispensing equipment, and manufacturer confirmation.

Dose

Dispensing process

UltiStrobe Applications in Dispensing Process Parameters

Connect equipment settings with droplet behavior and final dispensing quality to establish stable process windows faster.

UltiStrobe dispensing process parameter analysis

In Jet Dispensing, Micro Dispensing, or non-contact dispensing processes, droplet quality is governed by pressure, valve opening time, pulse width, frequency, nozzle diameter, viscosity, temperature, and standoff distance. UltiStrobe captures the complete droplet life cycle—from nozzle detachment and flight to approaching the substrate.

Analytical capabilities include droplet size and volume, velocity, direction, shape, ligament, satellite droplets, stability, and predicted landing placement. Excessive pulse or pressure can create larger droplets, longer tails, or satellites; viscosity and temperature changes can shift break-off timing and trajectory.

UltiStrobe enables rapid identification of stable process windows and early detection of nozzle clogging, wear, valve aging, or dispensing instability.

IJP

Inkjet analysis

Waveform Optimization & Droplet Formation Analysis

Drive voltage, rise time, fall time, dwell time, pulse width, and frequency directly shape each droplet produced by a piezo inkjet head.

Waveform Analysis

UltiStrobe reveals how waveform parameters influence formation, velocity, direction, tailing, and satellite generation in real time.

UltiStrobe IJP waveform analysis

Single Jetting Cycle

01Meniscus Movement
02Jet Formation
03Ligament Extension
04Pinch-off
05Satellite Formation
06Stable Droplet Flight

Key Assessment Items for IJP Process Development

  • Drop VolumeVerification against target dispensing volume
  • Drop VelocityConsistency across nozzles and waveforms
  • Jet Direction / AngleFlight deflection or nozzle misalignment
  • Drop ShapeProximity to an ideal sphere
  • Ligament LengthTrailing liquid ligament measurement
  • Satellite DropletQuantity, size, and spatial distribution
  • Drop-to-Drop RepeatabilityStability during continuous jetting
  • Nozzle-to-Nozzle UniformityConsistency across printheads
  • Frequency ResponseStability at increased frequencies
  • Predicted Landing PositionPlacement based on speed and angle
Drive waveform analysis

Figure 3 | Drive Waveform Analysis

Adjust voltage, pulse width, delay time, and frequency alongside real-time measurements to identify waveforms that deliver correct volume, stable velocity, minimal satellites, short tails, and high directional accuracy.

From observing droplets to tuning waveforms.

For IJP applications, UltiStrobe transforms droplet behavior into real-time feedback for waveform engineering—not merely confirmation of droplet ejection.

VIDEO 01

Application Overview

VIDEO 02

Technology Insights